Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Tattersall, J. E.
Right arrow Articles by Greenwood, R. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tattersall, J. E.
Right arrow Articles by Greenwood, R. N.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nephrol Dial Transplant (1993) 8: 60-63
© 1993 European Renal Association-European Dialysis and Transplant Association


research-article

Haemodialysis recirculation detected by the three-sample method is an artefact

J. E. Tattersall1,, K. Farrington1, P. D. Raniga2, H. Thompson3, C. Tomlinson1, C. Aldridge1 and R. N. Greenwood

1Renal Unit, Lister Hospital Stevenage, UK 2Department of Clinical Chemistry, Lister Hospital Stevenage, UK 3Department of Surgery, Lister Hospital Stevenage, UK

Correspondence and offprint requests to: Correspondence and offprint requests to: Dr J. Tattersall, Renal Unit, Lister Hospital, Stevenage SGI 4AB, UK.

The efficiency of haemodialysis may be limited by recirculation of blood between venous and arterial needles. Recirculation can be detected directly using a saline dilution method but is most commonly calculated from the urea concentrations of simultaneous samples from venous and arterial lines and a peripheral vein (three-sample method). The methods detect markedly different rates of recirculation in similar study populations. To investigate the possibility that the methods detect different phenomena, we performed both tests on 16 haemodialysis patients at various extracorporeal blood flow rates (Qb). The saline dilution method showed no recirculation in any of the patients, whereas the three-sample method indicated recirculation in all patients. The three-sample method indicated a mean recirculation fraction of 12.5% (SD 6.1) and was not influenced by changing Qb, suggesting that it was not detecting fistula recirculation. The three-sample method detects a solute concentration difference between arterial blood and peripheral blood during dialysis. There appears to be a disequilibrium between a central pool, represented by the arterial sample, and a poorly perfused peripheral pool, relatively isolated from the dialysis process, represented by the peripheral venous sample. The three-sample method for detecting recirculation should be abandoned.

Keywords: Cimino-Brescia fistula; disequilibrium; haemodialysis; recirculation; three-sample method


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.