Skip Navigation


NDT Advance Access originally published online on July 28, 2006
Nephrology Dialysis Transplantation 2006 21(10):2694-2696; doi:10.1093/ndt/gfl449
This Article
Right arrow Extract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
21/10/2694    most recent
gfl449v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Schwenger, V.
Right arrow Articles by Zeier, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schwenger, V.
Right arrow Articles by Zeier, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author [2006]. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Contrast-enhanced sonography as early diagnostic tool of chronic allograft nephropathy

Vedat Schwenger and Martin Zeier

University of Heidelberg, Division of Nephrology, Heidelberg, Germany

Correspondence and offprint requests to: Dr V. Schwenger, University of Heidelberg, Division of Nephrology, Im Neuenheimer Feld 162, 69120 Heidelberg, Germany. Email: vedat.schwenger{at}med.uni-heidelberg.de

Keywords: chronic allograft nephropathy; colour Doppler ultrasonography; contrast-enhanced sonography; kidney transplantation; renal allograft

A resistance index (RI) obtained by colour Doppler ultrasonography is a standard procedure in the routine diagnosis of renal allografts, and has recently been shown to be associated not only with allograft, but also with patient survival [1]. Although the value of colour Doppler ultrasonography of the renal allograft—especially in the early post-operative period—is undisputed, uncertainties persist as to its diagnostic and prognostic value and its clinical application. It is worth noting that RI not only reflects renovascular resistance, but also indirectly reflects haemodynamic parameters such as elasticity of the large upstream capacity vessels [2,3]. In the interpretation of RI values, surrogate markers for reduced vascular compliance such as intima media thickness, pulse pressure or—preferably if possible—pulse wave velocity should thus be ascertained [3]. In addition, it has been demonstrated that a threshold value of the RI of 0.8 is very limited and results in lower sensitivity and specificity in the diagnosis of, for example, chronic allograft nephropathy (CAN) [4]. CAN is difficult to diagnose by non-invasive methods and an estimation of the RI value is not a reliable tool for its diagnosis [5,6]. For this reason, the degree of CAN is frequently underestimated when using conventional colour Doppler ultrasonography, especially when post-transplantation serum creatinine is close to the normal range [4]. However, early diagnosis of CAN may play a major role in a long-term allograft survival and requires additional therapeutic interventions. Any technique which can evaluate the microvascular integrity of the renal allograft and which can image and quantify the perfusion of the allograft, is thus important [7,8].

A new option in the ultrasonographic diagnosis of biopsy-proven CAN is the real-time contrast-enhanced sonography technique (CES) [4]. Various animal and clinical trials have verified the practicability and safety of CES [9]. CES is a technique which is easy to perform, non-invasive, reproducible and provides the assessment of parenchymal blood perfusion. CES is based on the use of an ultrasonographic contrast medium containing gas-filled microbubbles, which is administered intravenously as a bolus injection for 10–20 s. Before application of the contrast medium, the imaging mode is performed with a low mechanical index in accordance with international guidelines for the use of contrast media in ultrasonography [10]. The initial visibility of the contrast medium occurs after a time of 15–30 s. When optimal renal visibility has been achieved after 35–50 s, a short-lasting pulse with a high mechanical index is transmitted to destroy the microbubbles. After the emission of the high-mechanical index, the ultrasound machine automatically reverts back to the low-mechanical index and the replenishment kinetics are recorded over a period of 10–20 s.

A region of interest (ROI) is subsequently placed in the renal cortex for quantitative analysis of the allograft tissue perfusion. Interlobar and arcuate arteries must be carefully excluded from the ROI. The images are analysed quantitatively offline. The maximum visibility of the contrast medium and its increase over time are obtained and calculated by means of an exponential function as described elsewhere [4].

It has been shown that, in cases of biopsy-proven CAN, CES is superior in terms of sensitivity and specificity than the simple estimation of colour Doppler RI in the diagnosis of CAN [4]. CES can evaluate microvascular integrity in renal allografts and is able to diagnose CAN early, i.e. before the increase of serum creatinine or before the onset of irreversible damage. By means of CES, CAN can be diagnosed more accurately and earlier than by conventional colour Doppler ultrasonography techniques. Further studies are, of course, necessary to confirm these investigations; in particular, the evaluation of the significance of CES in other diseases such as vascular rejection or calcineurin inhibitor toxicity. Although CES is a very promising procedure which enables early diagnosis of CAN, modern techniques such as CES are limited in clinical routine due to the lack of investigators’ experience with the new method and the lack of histological data necessary for the interpretation of new methods. Further studies are necessary because up to now, the number of renal allograft patients investigated by CES has been relatively small. In addition, in the case of bolus injection of the ultrasonographic contrast medium, the performance of the microbubble-containing contrast medium is probably not consistent and confounders may influence the calculation of the perfusion estimated in a ROI. The use of continuous infusion might provide more accurate results, however, bolus injection is an exact alternative and still feasible, as shown in earlier studies, and still presents a more practical approach in clinical settings [11,12]. It has not yet been determined what threshold value indicates a good cut-off point and, therefore, further studies are necessary.

In conclusion, the estimation of the colour Doppler ultrasonography RI alone in any diagnostic and prognostic interpretation, is as yet subject to many uncertainties. Modern techniques, such as CES, are very promising procedures which enable at least an early diagnosis of CAN. CES is not only associated with an improved diagnostic value compared with colour Doppler ultrasonography for the detection of CAN, but is also able to provide quantitative information on microvascular integrity and perfusion in an area of interest in kidney allografts. In addition, CES is a relatively cheap, non-invasive and reproducible technique.

Conflict of interest statement. None declared.



   References
 Top
 References
 

  1. Radermacher J, Mengel M, Ellis S, et al. (2003) The renal arterial resistance index and renal allograft survival. N Engl J Med 349:115–124.[Abstract/Free Full Text]
  2. Heine GH, Gerhart MK, Ulrich C, Kohler H, Girndt M. (2005) Renal Doppler resistance indices are associated with systemic atherosclerosis in kidney transplant recipients. Kidney Int 68:878–885.[CrossRef][ISI][Medline]
  3. Schwenger V, Keller T, Morath C, Krumme B, Zeier M. (2005) Intrarenal Resistance Index (RI) and Pulsatility Index (PI) of renal allografts depend on vascular stiffness of the transplant recipient. Abstracts Issue Of The American Society Of NephrologyPhiladelphia, USAJ Am Soc Nephrol 16: pp. F-Po988.
  4. Schwenger V, Korosoglou G, Hinkel UP, et al. (2006) Real-time contrast-enhanced sonography of renal transplant recipients predicts chronic allograft nephropathy. Am J Transplant 6:609–615.[CrossRef][ISI][Medline]
  5. Hilborn MD, Bude RO, Murphy KJ, Platt JF, Rubin JM. (1997) Renal transplant evaluation with power doppler sonography. Br J Radiol 70:39–42.[Abstract]
  6. Mallek R, Mostbeck GH, Kain R, Sunder-Plassmann G, Helbich T, Tscholakoff D. (1992) Polyetiology of renal allograft dysfunction. Does calculation of the resistive index still make sense? Acta Radiol 33:434–439.[ISI][Medline]
  7. Scholbach T, Girelli E, Scholbach J. (2005) Dynamic tissue perfusion measurement: a novel tool in follow-up of renal transplants. Transplantation 79:1711–1716.[CrossRef][ISI][Medline]
  8. Nankivell BJ, Chapman JR, Gruenewald SM. (2002) Detection of chronic allograft nephropathy by quantitative doppler imaging. Transplantation 74:90–96.[ISI][Medline]
  9. Jakobsen JA, Oyen R, Thomsen HS, Morcos SK. (2005) Safety of ultrasound contrast agents. Eur Radiol 15:941–945.[CrossRef][ISI][Medline]
  10. Albrecht T, Blomley M, Bolondi L, et al. (2004) Guidelines for the use of contrast agents in ultrasound. Ultraschall Med 25:249–256.[CrossRef][ISI][Medline]
  11. Korosoglou G, Hansen A, Hoffend J, et al. (2004) Comparison of real-time myocardial contrast echocardiography for the assessment of myocardial viability with fluorodeoxyglucose-18 positron emission tomography and dobutamine stress echocardiography. Am J Cardiol 94:570–576.[CrossRef][ISI][Medline]
  12. Lindner JR, Villanueva FS, Dent JM, Wei K, Sklenar J, Kaul S. (2000) Assessment of resting perfusion with myocardial contrast echocardiography: theoretical and practical considerations. Am Heart J 139 (2 Pt 1):231–240.
Received for publication: 9. 5.06
Accepted in revised form: 28. 6.06


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?



This Article
Right arrow Extract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
21/10/2694    most recent
gfl449v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Schwenger, V.
Right arrow Articles by Zeier, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schwenger, V.
Right arrow Articles by Zeier, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?